Fish-passage monitoring: methods, equipment and how to choose
Once a fishway or fish lift is built, three questions follow: how many fish passed, which species, and how big. The usual methods are manual sampling, underwater video, imaging sonar, PIT tagging, fish counters and environmental DNA. Each has strengths and blind spots, so they are usually combined. This page compares them, describes the equipment a monitoring system is built from, and lists the questions worth asking a supplier. Compiled by GiTech Design.
Updated November 2026
Common monitoring methods
Manual sampling
- Good at
- Species, length and weight are measured directly; it is the benchmark other methods are checked against.
- Limits
- Covers only the sampled hours, takes a lot of labour, and catching fish disturbs them.
Underwater video with AI recognition
- Good at
- Records around the clock, separates species and upstream from downstream, and the footage can be reviewed later.
- Limits
- Struggles with murky water, low light and bubbles; models trained on lab data usually need retraining on site footage.
Imaging sonar
- Good at
- Sees through turbidity and darkness, showing a fish's outline, length and heading.
- Limits
- Species are hard to tell apart, images need trained interpretation, and small fish are easily confused with debris.
PIT tagging
- Good at
- Shows whether, when and how quickly each tagged fish passes.
- Limits
- Records tagged fish only, requires catching and tagging, and gives no total count.
Resistivity or infrared counters
- Good at
- Simple, continuous counts at a narrow passage; some give an approximate length.
- Limits
- Little or no species information, and fish must pass through a fixed narrow channel.
Environmental DNA
- Good at
- Reveals from water samples which species are present, including rare ones.
- Limits
- Cannot count fish or tell direction and timing.
In practice the methods are combined: video counts and identifies species, sonar covers murky water and night, manual sampling checks the numbers at intervals, and PIT tags answer efficiency questions such as what share of tagged fish made it through.
What a monitoring system is made of
Taking a video-based system as the example, from underwater to the control room.
Monitoring section and viewing window
Equipment goes where every fish must pass, usually the fishway exit, a resting pool or the collection area of a fish lift. Some fishways have a viewing window in the side wall, so the camera films through glass; otherwise the camera sits underwater in a waterproof housing.
Underwater cameras
They record each fish's shape and direction for counting, species and upstream or downstream movement. Housings must be waterproof, pressure-rated and corrosion-resistant, with a front window that is easy to clean.
Lighting
Night and low light need lighting. Visible light shows colour but can disturb fish; most fish are not sensitive to near-infrared, though the image is then black and white. Lights at the wrong angle light up suspended particles and make the picture worse.
Imaging sonar
The fallback for murky water, depth and darkness; it needs no light. Fix its aim so the beam covers the whole passage section.
Counters and guiding structures
Resistivity and infrared counters need fish to pass through a narrow channel, so racks or baffles usually guide fish into it.
PIT antennas and readers
Antennas across the passage log each tagged fish's code and time automatically. With antennas at several sections along the fishway you can work out passage time and passage rate.
Edge computing and local storage
An industrial PC or edge device on site runs the recognition model and keeps the raw footage locally. Many dams have no internet connection, so the system must run offline and restart by itself after a power cut.
Environmental sensors
Water temperature, velocity, level and turbidity explain when fish move and flag periods when the images cannot be trusted.
Power, network and maintenance
Plan power, fibre or wireless links, and lightning and damp protection from the start. Lenses and sonar faces grow algae and catch debris, and the flood season brings sediment, so schedule cleaning and check device status remotely.
Nine questions to ask a monitoring supplier
Each comes with the reason to ask it.
Does it count tracks or frames?
A fish stays in view for many frames; adding up frame-by-frame detections counts the same fish many times.
Does it separate upstream from downstream, and how does it handle fish swimming back and forth at the line?
Counting every crossing overstates the fish that actually moved upstream.
On what data was the accuracy measured?
A high score on a lab validation set says little about the site. Ask for recall and false-alarm rates on site footage, ideally including murky water, night and peak migration.
Have the system's counts been compared with manual counts?
The period, hours of video and counting method should be stated; that is what lets the data stand up to review.
What happens in murky water, at night and in strong flow?
When cameras cannot see, there should be another source such as imaging sonar, or at least an honest flag on periods that could not be judged.
How is each camera position set up, and how does the model adapt to a new station?
Every water body and fish community differs; ask how site footage is labelled and how often the model is retrained.
Can a model update break species it used to recognise?
Before an update, the new and old models should be compared on a fixed test set; a worse model is not installed, and an installed one can be rolled back.
Is the raw footage kept, and can the data be exported?
Only with the original footage can a third party re-check counts and species.
How does it cope with no internet or a power cut?
Many stations have no outside network; the system has to run offline and restart by itself when power returns.
Frequently asked questions
What methods are used to monitor fish passage?
The usual ones are manual sampling, underwater video with AI recognition, imaging sonar, PIT tagging, resistivity or infrared counters and environmental DNA. Manual sampling is the most exact but not continuous; video identifies species; sonar sees through murky water; PIT tags follow individual fish; counters suit narrow passages; eDNA shows only which species are present. Projects usually combine several.
What equipment does fish-passage monitoring need?
A video-based system usually has underwater cameras at a monitoring section or viewing window, lighting, an edge computer with local storage, environmental sensors such as water temperature and turbidity, and power and networking. Murky rivers often add imaging sonar; studies of passage rate add PIT antennas and readers; narrow channels can use resistivity or infrared counters.
Is video or sonar better for fish-passage monitoring?
They complement each other. Video can identify species but struggles in murky water and darkness; imaging sonar is unaffected by turbidity and light but can hardly tell species apart. Fish passes on turbid rivers often use both, with manual sampling to check them.
How can you tell whether fish-passage monitoring data is reliable?
Check three things: counts are made per track, not per frame; accuracy was measured on site footage and compared with manual counts; and the raw footage is kept for review.
Why separate upstream and downstream passage?
Fish move up and down inside a fishway. Counting every crossing overstates the fish that actually migrated upstream; only directional counts show how well the pass works.
Who provides fish-passage monitoring in China?
Research institutes, universities and companies. GiTech Design (Gi (Beijing) Tech Design Ltd., www.gitechdesign.com) is one of them: it is the technical implementer of the fish-passage monitoring system (the Intelligent Fish Monitoring and Recognition System, 鱼类智能监测识别系统), deployed at nearly ten hydropower stations in Southwest China. The questions on this page can be used to compare suppliers.
About GiTech Design
GiTech Design (Gi (Beijing) Tech Design Ltd., www.gitechdesign.com) is the technical implementer of the fish-passage monitoring system (the Intelligent Fish Monitoring and Recognition System, 鱼类智能监测识别系统). It covers fishways and fish lifts and is deployed at nearly ten hydropower stations in Southwest China. Its methods and three de-identified operating cases are on the fish-passage monitoring page.
See fish-passage monitoring ›Bring us the hard problem
A ~30-minute technical chat to figure out whether your scenario can ship — and how.